electromagnetic flow meter krohne

Need it ${ shippingArrivalDayOfWeek }, ${ shippingArrivalDate.format('MMM. A full on-site verification of the flowmeter without process interruption can be carried out using the OPTICHECK service tool. Closed weekends & holidays, We have Mandals Drag Hose and Mainline Hose in stock for immediate shipment. electromagnetic No grounding rings needed, Long term reliability and maintenance free. Leading metrological institutes use the OPTIFLUX 5000 as their master meter in combination with the high-end signal converter IFC 300. This assembly comes with the 6 OPTIFLUX 4100 body, flow converter and 30 cable. You can switch them off or delete collected information if you prefer. krohne optiflux flow split electromagnetic meter larger

The TIDALFLUX 4000 flow sensor with integrated and non-contact capacitive level measuring system provides accurate flow measurement in partially filled pipes. The strenghts of the WATERFLUX 3000 sensor lies in its unique construction with a rectangular and reduced cross section and its efficient coil construction. Don't have an account? (wus)*b= qIhmi:x=%7_-"-d? endstream endobj 387 0 obj <. It comes with a selection of chemically resistant liners and electrodes. {{name}}: {{value}} {{#each pushedProductsPlacement5}}, With DirectIndustry you can: Find the product, subcontractor or service provider you need | Find a nearby distributor or reseller| Contact the manufacturer to get a quote or a price | Examine product characteristics and technical specifications for major brands | View PDF catalogues and other online documentation. The traditional grounding of EMFs has been done through : Grounding to electrically conductive pipes - The liquid is in direct contact with the metal of the pipe and therefore it has the same potential as the grounded pipe. This website uses cookies to provide statistics that help us give you the best experience of our site. However, this can be problematic for wetted material compatibility and the need for exotic metals for the grounding rings, which can be cost prohibitive. Its long-term reliability and durability make it the ideal flow sensor for the water industry for measuring abstraction water, drinking water, waste water, sewage and effluent. The OPTIFLUX 4000 electromagnetic flow sensor is the standard in the process industry and suitable even for demanding applications. As world market leader, KROHNE produces electromagnetic flowmeters in the Netherlands, Brazil, India and China. coolants, cold/hot water, chemicals, etc. No moving parts, no wear and no obstruction in the flow, Optional KGA 42 external datalogger and GSM module for remote data transfer, Measurement of raw water and irrigation water, Design enables high speed filling with minimal product loss, Long term reliability due to extreme high dimensional stability, Absolutely leak-free stainless steel housing concept (DN10 and DN15), Fruit juices and other fluids with fibres, Available inputs and outputs: Current output (incl. ${ getSpecToDisplayByCategoryAttributeId(attribute.id) }, ${ _getVar(combination, 'custom_description') }, ${ _getVar(combination, 'additional_notes') }, ${ getWarehouses().map(s => s.address + ', ' + s.city + ', ' + s.state).join(' / ') }, ${ combination.length } x ${ combination.width } x ${ combination.height }. 'N/A' : option.value }. BATCHFLUX 5500 C is the industrial standard for volumetric filling machines.

KROHNE offers its customers a comprehensive application and process diagnostics package far beyond what device diagnostics normally offer. To get more information please expand the product block by pressing on image or product title. PN16/ ASMECl150. 2022All rights reserved ${ option.value == null ? With Virtual Reference, the flow sensor can be installed in any pipe or process without the need for additional grounding. ~]0D(qq@eF~zUd0i70(PfN(G> u'(dKxk7g |* uB>K%0HB*r , U{H TymE)\`g!T%3Op!C[#-KD5_?/pS~V Cast Iron Flange 6" (Slightly Used One Season), Cast Iron Flange 4" (Slightly Used One Season), Plastic Pressure Regulator 4" Victaulic and 3" FPT (Slightly Used One Season), https://irrigationsupplyparts.com/wp-content/uploads/VI_OPTIFLUX_Family_EN_web.mp4, Hex Drive Stainless Steel Socket Cap Screw, Bi-directional flow measurement over a wide dynamic range (turndown ratio: 1000:1), PTFE, PFA, ETFE, hard rubber, soft rubber or PU liner: excellent chemical and abrasion resistance, Special designs, sizes, inner diameters and liner thicknesses on request, Standard measurement accuracy: 0.3% or 1mm/s of measured value (MV), Optional external coatings for offshore or subsoil installation (also acc.

Receive updates on this section every two weeks.

to MIDMI-001 and OIMLR49 accuracy class1, Flange: DN253000/ 1120", max. 0 It is the most accurate mag meter for filling applications with filling in the food sector endstream endobj startxref The latest alternative to traditional grounding: Virtual Reference. Call Cedric at 517-458-9741 for details. Please enable javascript in your browser to use this website properly. Reference: "Desalination Plants Benefit from Mag Meters with Unique Virtual Reference Feature" Joe Incontri, Director of Marketing KROHNE USA; 2013. Coriolis mass flowmeter for linear and rotating filling machines Lower cost of install for chemically aggressive fluids - save costs on exotic materials for grounding rings. The sensor has the widest diameter range available in the market: from DN25 up to DN3000.

fault response time of only 2minutes, SIL 2/3 up to DN600/ 24"; non-SIL up to DN2000/ 80" (larger on request), Cost-effective flow measurement of liquids (5S/cm) up to +120C/ +248F, Extra isolation of electronics for use in high humidity areas, Wafer-style design: DN10150/ 6", max. Meets potable water standards: ACS, DVGW, NSF, TZW, WRAS etc. The OPTIFLUX 7300 combines the advantages of non wetted capacitive electrodes, a ceramic liner and the IFC 300 converter. The OPTIFLUX 2000 electromagnetic flow sensor is the specifially develloped for water and waste water applications. Primary industries for EMFs include food and beverage, chemical, water/wastewater, pharmaceutical, and water or utility applications. The instrument is economical due to low investment and maintenance costs; it is ecological due to accurate measurements and no waste. It enables reliable flow measurement even under harsh process conditions with temperatures up to +180C/ +356F, low conductivity (5 S/cm) and solid content (up to 10%). An intuitive operating concept featuring a quick start function for simple start-up.

The OPTIFLUX 4300 is an electromagnetic flowmeter (EMF) for advanced process applications with aggressive liquids or abrasive media. 50mm VAC Krohne Optiflux 2100 Flow Meter, 80mm VAC Krohne OptiFlux 2100 Flow Meter, 100mm VAC Krohne OptiFlux 2100 Flow Meter, 125mm VAC Krohne OptiFlux 2100 Flow Meter, 150mm VAC Krohne OptiFlux 2100 Flow Meter, 200mm VAC Krohne OptiFlux 2100 Flow Meter, 400mm VAC Krohne OptiFlux 2100 Flow Meter, 50mm VDC Krohne Optiflux 2100 Flow Meter, 80mm VDC Krohne OptiFlux 2100 Flow Meter, 100mm VDC Krohne OptiFlux 2100 Flow Meter, 125mm VDC Krohne OptiFlux 2100 Flow Meter, 150mm VDC Krohne OptiFlux 2100 Flow Meter, 200mm VDC Krohne OptiFlux 2100 Flow Meter, 250mm VDC Krohne OptiFlux 2100 Flow Meter, 400mm VDC Krohne OptiFlux 2100 Flow Meter, 250mm VAC Krohne OptiFlux 2100 Flow Meter, 300mm VDC Krohne OptiFlux 2100 Flow Meter, 300mm VAC Krohne OptiFlux 2100 Flow Meter, 350mm VDC Krohne OptiFlux 2100 Flow Meter, 350mm VAC Krohne OptiFlux 2100 Flow Meter, Bi-directional flow measurement over a wide dynamic range, Optional for subsoil installation and constant flooding, Proven and unsurpassed life time, huge installed base, PP, PO or hard rubber liner: suitable for low concentrated chemicals, Proven and unsurpassed lifetime, huge installed base, Standard measurement accuracy: 0.3% or 1mm/s of measured value (MV). With KROHNE flow meters, the liners are typically Hard Rubber, different elastomers, or ceramic liners for extremely corrosive applications. KROHNE solves these problematic grounding methods with Virtual Reference, sometimes referred to as "virtual grounding." The user has a precise overview of the process at any given time thus fulfilling from A to Z the constantly increasing requirements of an optimal process. In processes with cathodic corrosion protection or galvanization, a voltage is present across the electrodes and earth ground. All standard water and wastewater applications, Water treatment plants (raw water, drinking water, treatment chemicals), Desalination plants (sea water, permeate, brine), Industrial water (process or production water, cooling water, boiler feed water etc. 407 0 obj <>/Encrypt 387 0 R/Filter/FlateDecode/ID[<88AEFC5229247EA6DC26FA5CB66E9CDE>]/Index[386 33]/Info 385 0 R/Length 99/Prev 638336/Root 388 0 R/Size 419/Type/XRef/W[1 2 1]>>stream Its zirconium oxide liner guarantees extreme long-term dimensional stability and therefore no change in repeatability of filling volumes over long periods of time. Looking for even more savings? Learn More, Get notified on new and inbound inventory, 4901 Rockaway Blvd NE, Rio Rancho, NM 87124. Diagnostics incl. The wall of the sensor tube itself is electrically isolated with only the electrodes contacting the fluid. The measuring principle is based off of Faraday's Law of Induction, where the voltage that is induced at the electrodes is directly proportional to the velocity of the liquid moving within the magnetic field. Solve Electromagnetic Flow Grounding Issues with KROHNE Virtual Reference. The OPTIFLUX 6300 is an electromagnetic flowmeter Modbus, FF, Profibus-PA/DP, PROFINET The new patented technology works by measuring the fluid's electrical potential at the electrodes and creating an offsetting voltage that eliminates the induced electrical noise. This is the result of a special tube design with conical parts, optimizing the flow profile. Subscribe to our monthly newsletter for coupon codes! That is why leading metrological institutes use the OPTIFLUX 5300 as their master meter. Legend: Suitable Suitable with conditions. With our newsletter, you will receive up-to-date information on trends and developments in the various industries, our products and solutions as well as information on our trade fairs and academies. 5 47058 Duisburg Germany, From basic applications to demanding flow and custody transfer (CT) measurements, Designs and liner materials for various applications - from potable water to extremely adhesive, abrasive or aggressive fluids, Large choice of nominal sizes up to DN3000 / 120", Certified for safety applications up to SIL 2/3, with automated partial proof test capability for extended proof test intervals, Best-in-class diagnostic test interval incl. KROHNE Messtechnik GmbHLudwig-Krohne-Str. The OPTIFLUX 7300 is a an electromagnetic flowmeter (EMF) for measuring very low conductivity liquids (0.05 S/cm). Modbus), Integrated temperature and pressure measurement for leak monitoring, CT: MI-001, OIMLR49 up to DN600/ 24", no inlet/outlet runs needed, From raw water measurement to drinking water metering in distribution networks, Up to DN600/ 24", max. Techical datasheet : OPTIFLUX5000SANDWICH.pdf.

Thanks to DN25 / 1" 5 Triton Avenue Further details are contained on this page below, and in the data sheets available for download. Mount Maunganui i.fb-icon-element.fontawesome-icon.fb-icon-element-2{ color: #ffffff;}i.fb-icon-element.fontawesome-icon.fb-icon-element-2:hover { color: #ffffff;}Same Day Shipping Services, i.fb-icon-element.fontawesome-icon.fb-icon-element-3{ color: #ffffff;}i.fb-icon-element.fontawesome-icon.fb-icon-element-3:hover { color: #ffffff;}See our store specials, i.fb-icon-element.fontawesome-icon.fb-icon-element-4{ color: #ffffff;}i.fb-icon-element.fontawesome-icon.fb-icon-element-4:hover { color: #ffffff;}Great online pricing. The liners and electrodes must be suitable and chemically compatible with the application.

The meter is the ideal solution water meters, the WATERFLUX 3070 is maintenance-free and offers a much larger turn down ratio (1000:1). Its wear resistant liner materials as well as its full bore design without moving parts make the OptiFlux 2100 an effective replacement of mechanical water meters in drinking water distribution networks. Tauranga Interested in viewing a product selection list of all the KROHNE flow measurement lines? Use tab to navigate through the menu items. PN40/ ASMECl300, Compact version up to IP69, remote version IP68. For several decades, Electromagnetic Flowmeters (EMFs) have been the primary choice for measuring volumetric flow of conductive liquids through pipes. {{/end}} This flow technology is especially effective for water-based media or fluids with a minimum 5-20 micro Siemens of electrical conductance. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. after an elbow or reducer (MID / OIML R49 certified), Submersible in flooded measurement chambers (IP 68 / NEMA 6P), Special coating for subsurface installation. The high-end meter is particularly suitable for applications requiring high accuracy and PROFINET Due to its full bore design without moving or intruding parts, there is no pressure loss and no maintenance required. Flow measurement of conductive liquids, acids and bases right down to difficult applications such as: Swimming pools and recreational facilities, Precise dosing of liquid fodder, liquid fertilizers, measurement of liquid manure, sprinkler irrigation systems, Vehicles, fire extinguishing systems: foam mixing, control of sprinkler systems, Heat counters, energy allocation to buildings and workshops, Drinking water approvals including KTW, WRc, KIWA, ACS, Suitable for underground installation and constant flooding (IP 68), Compliant with requirements for custody transfer (MID MI-001, OIML R49, ISO 4064, EN 14154), Standard in house wet calibration of sensors up to diameter DN3000, With virtual reference option grounding rings can be omitted and installation is simplified, Rugged liners suitable for all water and wastewater applications, More than 300,000 units operating in the field, Works reliably under demanding conditions: High temperatures (up to 180C / 356F) and low conductivity (non-water from 1 S/cm, water from 20 S/cm), Chemically resistant to alkaline solutions and acids, For slurries and pastes with high solids content, Excellent long-term stability and accuracy, Fused in-place Cermet or platinum electrodes, Transfer standard of international metrological authorities, For acids, alkaline, paste, slurries and many other aggressive media even with high solid contents, Robust stainless steel housing for hygienic and aseptic operation, PFA liner reinforced with embedded stainless steel grid, High form stability for good accuracy even with high pressures, Unique L-shaped gasket prevents expansion of gasket into measurement tube, Typical food and beverages and pharmaceutical process connections and insertion lenghts, Conductivity 1 S/cm (for demi-water 20 S/cm), Beverages including soft drinks, beer, wine and fruits juices, Beverages containing solids (for example yoghurt containing cereals), Drugs, caustic sodas, acids, proteins, antibiotics, CIP media including acids and caustic solutions, For large-scale production plants with diameter up to DN150, Reliable readings even in case of pulsating or fast changing flows due to rapid signal processing, Low power consumption and operating costs, Protection classes "I", "e" or "d" selectable by the user during installation, The only 2-wire electromagnetic flowmeter suitable for conductivities down to 5 S/cm, Excellent chemical and abrasion resistance, Increased safety and hygiene with absolutely leak tight design, Sterile and hygienic; conformity to FDA requirements, Excellent long term stability and accuracy, Alternative for mass flowmeter (for the price of an electromagnetic flowmeter), Low conductive mediums: (bio-) alcohols, spirits, glycols, glycerine, Water mixed with oil or metallic particles, Dairy products: fat creams, milk, cheese, yoghurt with fruit particles, For partially filled pipes in the water and wastewater industry, High abrasion resistance and chemical resistance, Measurement possible between 10% and 100% filling, Electrodes for flow measurement are below 10% filling level, therefore no blind folding by fat and oil floating on the water surface, Complete factory calibration - no on-site calibration necessary, For partially filled pipes instead of expensive siphon tube constructions, Stand alone water meter with battery lifetime up to 15 years, Unique rectangular sensor construction results in good low flow performance, a large ratio an very low power consumption, Large measuring range. The electromagnetic signal converter IFC 300 is designed to measure the flow velocity, conductivity, volume and mass flow of electrically conductive liquid media. To get detailed information about specific product you can download Technical datasheet file by clicking corresponding link.

Utilization of grounding rings between the pipe and the meter before and after the meter - The rings will be in contact with the liquid, along with the meter electrodes, ensuring that they have the same ground reference point for the measurement. The OPTIFLUX 6000 electromagnetic flow sensor is specifically designed to stay clean and sterile in compliance with the most stringent demands prevailing in the food & beverages and pharmaceutical industries. 386 0 obj <> endobj The OPTIFLUX 2300 is an electromagnetic flowmeter (EMF) for all demanding applications with water and wastewater. DD') }? This electromagnetic flowmeter can be used for noisy applications, low conductivities, mediums tending to form an insulating film, applications with high vibrations, and oxidizing, abrasive and toxic mediums. Unlike the basic version OPTIFLUX 4050, the OPTIFLUX 4100 features higher accuracy. The voltage is then used as the reference potential at the flow converter for signal processing. 3116, Copyright 2022 - Irrigation Express. Grounding with grounding electrodes - having exotic materials at the grounding electrode means lower cost on the material, but also means less surface for the ground to be in contact with the fluid. hbbd``b`9$@v bl 5@D9 8`AbN@BBHHK i&FFaD[ 9TR Meter size: DN2.5150 / 1106" (3A, EHEDG certified) conductivity, electrode error, ambient and process temperature etc. 418 0 obj <>stream

Please fill out the following information to request a quote for the 1x selected products. The integrated level sensors in the liner are in no contact with the liquid and are therefore insensitive against fat and oil floating on the surface. 8 a.m. to 4 p.m. EST Process pressure: 0 bar - 40 barProcess temperature: 0 C - 120 C. Best-in class temperature range, accuracy, pressure drop and flow range, Ultra-compact design for parallel installation and tight spaces, 420mA, pulse, frequency, Modbus, IO-Link, High accuracy (0.2%), with CT approvals (OIMLR49, MI-001), 0D/0D installation acc. Please try again later. ), Industrial wastewater collection, treatment and return flows, KCURCABLE - Krohne Current Cable - per meter, KSIGCABLE - Krohne Signal Cable - per meter, KMAGWIRING - Wiring Termination & Connection to Krohne Flow Sensor, KMAGPOTTING - IP68 Potting & Cable Termination for Krohne Flow Sensor -, Available in 10-30VDC or 230VAC models - Please contact to specify, AS2129 Table E & AS4087 PN16 Flanges available, IP68 version available for below ground installation. ;s(jQz-~PT>FAJeZ9S^gh ku>o0cyDPc5qPW+U2F.v13jnyI Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.

Proper grounding of the EMF is critical for ensuring a fixed reference potential for the small millivolt signal voltage in order to provide accurate measurement. to ISO 12944). Techical datasheet : TIDALFLUX4300F.pdf. Meter size: DN815 (FDA, EC1935/2004 etc.) Learn More, Create a Free Account for New Benefits! {{#each pushedProductsPlacement4}}, {{#pushedProductsPlacement5.length}} With its resistance measurement and noise measurement, the IFC 100 lays the foundation for even more process transparency and reliably reports about: IFC 100 for all standard applications- the most innovative converter line. Techical datasheet : BATCHFLUX5500C.pdf. %%EOF during change of media or empty tube), Compact, remote field, wall-mounted and rack-mounted housing, With many sensor and process diagnostics for standard requirements, 4-wire, 420mA, pulse, frequency, status, HART. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates. Full bore design: No moving parts, no wear, no pressure loss. A full on-site verification of the meter without process interruption can be carried out using the OptiCheck service tool. These devices continually measure all decisive parameters and convey information about the condition of the device, the quality of the measured value and potential application errors. {{/each}}. The coils provide a stronger and more homogeneous magnetic field, leading to an improved signal to noise ratio. Diagnostics incl. Installation in measurement chambers subject to (constant) flooding is also possible using the optional IP68 / NEMA 6P rated version. The OPTIFLUX 1300 is an electromagnetic flowmeter (EMF) with lightweight wafer-style design. The BATCHFLUX 5500 is an electromagnetic flowmeter (EMF) for rotary or linear filling machines. High accuracy at peak flows during the day and at low flows during the night, Certified to OIML R49 class 1 & 2 and MID Annex MI-001, Optional verification to MID Annex MI-001 for water meters (Module B and D), No inlet or outlet sections required when installed e.g. {{#pushedProductsPlacement4.length}} conductivity, electrode error, ambient and process temperature etc.

The OPTIFLUX 1000 electromagnetic flow sensor is the economic and ecological solution for various industries, ranging from agriculture to utilities and from fire fighting to machinery. Full bore design: No moving parts, no wear, no pressure loss, On-site verification of flowmeter with OPTICHECK service tool, Standard applications with clean, aggressive or abrasive liquids, Changing or excessively low conductivity (e.g. The TIDALFLUX 2300 is an electromagnetic flowmeter (EMF) with a patented, capacitive level measurement for use in partially filled pipes (up to DN1600 / 64). PN40/ ASMECl300, Economical flow measurement of liquids (5S/cm) with solid content (10%), Economical flow measurement of liquids (5 S/cm) with solid content (70%), Liner materials resistant to low concentrated chemicals, With extra isolation of electronics for use in high humidity areas, Flange: DN251200/ 148", max. The IFC 100 can be freely combined with KROHNEs entire standard series of electromagnetic flowmeters.The IFC 100 was designed for applications requiring an economical measuring solution with a high level of technology. There was an error trying to send your message. Create Your Free Account for Preferred Pricing, Extended Warranties, & Much More! 3 x 420 mA, HART, Modbus, FF, Profibus-PA/DP, PROFINET Thank you for your message. It is the ideal solution for all general flow applications where reliable flow measurement with sufficient yet not extremely high accuracy is required. PN16/ ASMECl150; others on request, Battery- or mains powered, with battery backup option (incl. It has been sent. OPTIFLUX 4040 C is an electromagnetic flowmeter in 2-wire technology with the dynamics, reliability and accuracy of a 4-wire EMF.

The OPTIFLUX 5000 is one of the most accurate flowmeters available in the market today. The IFC 100 is a 4-wire electromagnetic signal converter. OPTIFLUX 4040 C is suitable for steady or pulsating flows. In many applications, traditional grounding methods for EMFs pose problems. HART), pulse/frequency output, status output and control input, Large backlit graphic display with intuitive operation, A variety of operating languages integrated as standard, Heating, Ventilation & Air Conditioning (HVAC), Water distribution networks and spray-irrigation systems, High measuring accuracy and long-term stability : 0.15% of measured value 1 mm/s, Optimal zero point stability independent from product properties, Superior process reliability thanks to standard integrated diagnostics: testing of device functions, check for compliance with specifications and application testing, Available inputs and outputs: Current output (incl. Choose the flowmeter that best matches your application from the following table. The Krohne OptiFlux is an electromagnetic flow meter (EMF) for standard water and wastewater applications. The OPTIFLUX 4100 is an electromagnetic flowmeter (EMF) for a wide range of standard process applications with aggressive and abrasive liquids. Dismiss. For more information, please see the article below for practical examples where this technology has solved challenges in volumetric flow using electromagnetic flowmeters.

Sitemap 20

electromagnetic flow meter krohne

This site uses Akismet to reduce spam. rustic chalk paint furniture ideas.